• Smart Rooms
    • How Radiant Heat Works
    • Rooms Become Space
    • Comfort Control
    • Product Matrix
    • FAQs
    • Request Information
    • Art of Being Smart
    • Health & Safety
      • Why Baseboard Heating Isn't Smart
      • Why Forced Air Heating Isn't Smart
    • System Comparison
    • Request Information
    • Smart Solutions
    • Comfort Controller
    • Radiant Ceilings
    • Suspended Ceilings
    • Architectural Series
    • Floor Warming Systems
      • SmartRooms Installation Detector
    • Earth Storage System
    • Warranties
    • Request Information
    • Technical Resources
    • Installation Guides
    • Specification Details
    • Engineering Documents
    • Media Files
    • Warranties
    • Owner Manuals
    • Time Saving Devices (S.I.D)
    • Request Information
    • About ThermaRay
    • Relationships
    • Market Presence
    • Contact Us
    • Opportunities
    • Request Information
radiant heating
Smart Solutions

Operating Manual For SmartRooms Installation Detector

INTRODUCTION

S.I.D was designed to help the installer detect problems as they occur in order to avoid a more costly return service call. S.I.D does the following:

  • NO CONTINUITY - The heating cable has been cut and must be repaired.

  • LEAKAGE - S.I.D will buzz if there is electrical leakage between the steel braid and heating cable. This will not cause the GFCI (ground fault circuit interrupter) to trip but indicates a potential problem and should be fixed. All Therma-Ray Floor Warming Systems are tested for this prior to leaving the plant.

  • SHORT - S.I.D will buzz when there is an electrical short measuring higher than 5mA (milli-amp). The short occurs between the steel braid and the heating cable. The system has been damaged and must be repaired.

    Repair kits are readily available from the distributor where you purchased your Therma-Ray Floor Warming System.

    NOTE: You may wish to use an ohm meter to verify S.I.D's test.

  1. Take the red clip and connect it to the bare wire of the white lead wire. Do the same connecting the black clip to the black lead wire. Connect the green clip to the steel braid (see diagram). Turn S.I.D on. If there are no lights or buzzing then the cable is good. Turn S.I.D off and disconnect so that you can install the floor warming system.

  2. Start installing the cable system by placing one end of the wire leads from the wire spool into the thermostat wall box.

  3. Connect S.I.D as shown.

  4. Turn on S.I.D

  5. Continue to install the floor warming system as per instructions.

    Note: If the cable system is damaged during installation there will be a buzzing sound and a light will be on.

  6. After the floor warming cable installation is completed turn S.I.D off. Disconnect the RED or BLACK clip from the wire. Attach the RED or BLACK clip to the other wire. Now there should be a clip on each non-heating lead wire and a clip on the steel braid (see picture below). Turn S.I.D on. If there is no buzzing and all lights are off then the system is ok.

    NOTE: If buzzing occurs and any lights are on, the wire is damaged.

  7. Finish installing your floor. S.I.D should be kept on during all stages of the floor installation right up to and including when grout is applied. Using S.I.D this way protects you, the installer, from having to effect a repair. To conserve batteries turn S.I.D off at night or when you are not working on the floor. Note: If S.I.D has been used correctly, it should significantly reduce service calls.

Therma-Ray Inc.
670 Wilsey Road, Fredericton, NB
Canada E3B 7K4
Tel: 506-457-4600 Fax: 506-457-4699
E-mail: sales@Thermaray.com
www.thermaray.com

Revised August 2005